Help needed please.
I'm trying to sort out those little niggles that come with a build entirely from separate parts. I am using a complete engine and loom from a Unitrak and have a problem with the charging system. I have tested 48volts AC from the generator at 4,000rpm and have tried a reg/rec which I know is good. I only get 12.6 - 12.8 volts at the battery once running. My manual suggests the possibility of weak generator magnets as whilst everything bench tests okay once under load nothing much appears to be happening.
Any tips would be appreciated.
Hello Guest User,
Please feel free to have a look around the forum but be aware that as an unregistered guest you can't see all of it and you can't post.
To access these 'Registered Users Only' areas simply register and login.
Please feel free to have a look around the forum but be aware that as an unregistered guest you can't see all of it and you can't post.
To access these 'Registered Users Only' areas simply register and login.
Unitrak charging.
Moderators: chrisu, paul doran, Taffus, KeithZ1R
Unitrak charging.
Asphalt Cowboy Z1100R, 1981 Z1000J
Hi Chris, a good lead acid type battery should give 2,2 volts per cell ie 13.2 volts with the voltage rise you are seeing would expect a decent reading with good battery though 14.6 v is deal,as a double check wire a multimeter set to dc amps in series with the positive side of battery to show battery is accepting charge.Cheers Paul j
PAULJAC47,,,,,"She may not look like much, but she's got it where it counts, kid."
-Han Solo
You can't polish a turd, but you can roll it in glitter
Salad is what real food eats.
Anon
PUM 673
-Han Solo
You can't polish a turd, but you can roll it in glitter
Salad is what real food eats.
Anon
PUM 673